I just finished manualy assigning the same 3 universal device pollers to roughly 800 interfaces - these interfaces were spread over 80 devices - you can imagine the time it takes :) I'm really missed a "filter" field in the new Webbased device manager - Right now you can filter on Node...
Posted to
Orion Feature Requests
(Forum)
by
uscallesen
on 07-10-2008
Filed under: Universal Device Poller
Rounding Numbers in Universal Device Poller
I got upgraded to Orion v9 yesterday and immediately started playing with the Universal Device Poller. I love it! I am pulling SNMP tables off my NetApp filers and generating reports on snapmanger results, volume usage, etc. But, I have a need to round some numbers so it looks prettier on the website...
Posted to
Orion Network Performance Monitor
(Forum)
by
andrew
on 07-10-2008
Filed under: Universal Device Poller
Creating a guage from UnDP
Has anyone been able to create a guage off of a universal device poller that is polling a table? In my case, I'm polling an HP R3000 XR UPS that has 3 phases. I want to create a guage for the phases, but I can't figure out a way. The best I can get is a chart, but I'm trying to create a UPS...
Posted to
Orion Network Performance Monitor
(Forum)
by
branfarm
on 07-11-2008
Filed under: Universal Device Poller
Displaying Poller Data from a Get Table
Hi All. I have just upgraded to v9 and I am using the new Universal Device Poller to do a GET TABLE on a table containing Windows Service information (name, state, start type, etc). I am able to perform the test just fine and I get back data. What I am going for here is column A from the GET TABLE contains...
Posted to
Orion Network Performance Monitor
(Forum)
by
mikeharris
on 07-12-2008
Filed under: Custom Poller, Universal Device Poller, Get Table
Share Your Universal Device Pollers!
In Orion 9.0, we introduce Universal Device Pollers. These pollers can be exported and imported, which means that they can be shared on Thwack! You can post your pollers and download other pollers here: http://thwack.com/files/folders/pollers/default.aspx
Posted to
Orion Network Performance Monitor
(Forum)
by
denny.lecompte
on 07-23-2008
Filed under: custom MIB poller, Universal Device Poller
Re: Help with monitoring temperatures on Cisco devices via the Universal device poller
Bericks999, If you paste that OID, you don't need to touch the settings under "Show Advanced Options". If it's in our MIB database and the name and description auto-populate, my advice is to not even look at that option. That's why we hid it by default. You really only need that...
Posted to
Orion Network Performance Monitor
(Forum)
by
denny.lecompte
on 08-01-2008
Filed under: Universal Device Poller
Re: VM Monitoring
You can use the the Universal Device Poller to monitor a lot of different values on an ESX server. It helps to know the OIDs in order to build the UnDPs, and you can find most of what's available from ESX here: http://www.oidview.com/mibs/6876/VMWARE-VMINFO-MIB.html
Posted to
Orion Network Performance Monitor
(Forum)
by
denny.lecompte
on 08-01-2008
Filed under: VMware, ESX, Universal Device Poller
(Emerson) Liebert 300 UPS Customize Poller
Hello. I have Liebert 300 UPS, and tried to use different MIBs from universal poller but most of them does not work, giving out error "OID is not supported". Specially the Traps are not working from MIB Tree. Am i missing something here? Should i open up a case with Orion to solve this? Can...
Posted to
Orion Network Performance Monitor
(Forum)
by
mkazimh
on 08-10-2008
Filed under: Universal Device Poller
Universal Device Poller adding information to Historical - Custom Poller Report
I created a new Universal device poller to gather CISCO Serial number information using the OID 1.3.6.1.4.1.9.3.6.3. I am using the Raw Value SNMP Get Table options. I see this table information appear on the Node Details page from the Website I would like to add this information to a Historical Custom...
Posted to
Orion Network Performance Monitor
(Forum)
by
mrpinkfloyd
on 10-06-2008
Filed under: report writer, Universal Device Poller, UnDP universal device poller
Sum and transform universal device pollers to get Total power output of PDUs
I have a load of APC metered PDUs which i am using a universal device poller to get amps used on each PDU. I would like to display live and historically - preferably in a chart as well - the toal power being used by the PDUs. Is there any way to sum the results of all of the pollers and then transform...
Posted to
Orion Network Performance Monitor
(Forum)
by
ChrisR99
on 12-01-2008
Filed under: Universal Device Poller, UnDP universal device poller, undp, universal device pollers